A secondary Operating
Panel may be connected to the Processor Unit. This may be useful
in conjunction with a second display if you wish to control the MF90 system from two different locations
on your vessel.
The Operating Panel
is installed as specified in the Installation manual. The Processor Unit is turned on. The following specific
items are required for this task:
- Computer mouse
- Computer keyboard
- Ethernet switch (Make sure that your
selected Ethernet switch has a large bandwidth capacity. Minimum 1 Gb (1000BASE-T)
is required.)
- Ethernet cables (It is very important
that high-quality Ethernet cables are used. You must use Cat 5e STP (Shielded Twisted Pair) quality or better.)
Neither tools nor instruments
are required.
When supplied, the Operating Panel is set up with
the following communication parameters:
- IP Address: 157.237.60.20
- Subnet mask: 255.255.255.0
- Gateway: 157.237.60.1
The IP and MAC addresses
for your Processor Unit are contained in a text file named IPandMACaddress.txt. The file contains the
product name, IP address and MAC address in the following format (example):
MF90157.237.60.14AC:1F:6B:1D:42:E6 |
Tip: If the distance between
the Processor Unit and your second display is considerable, we suggest
that you use KVM (Keyboard Video Mouse) technology to preserve the
video quality.
- Make the following
preparations.
- On the Processor Unit, close any programs that are
running, and return to the desktop.
- Insert the Ethernet
switch between the Operating Panel and the Processor Unit.
Make sure that you
use the correct Ethernet socket on the rear side of the computer: ETH1
- Install the secondary
Operating Panel.
- Connect the Operating
Panel to AC mains.
- Connect the power cable from the Ethernet switch to
the AC power outlet.
- Do not connect
the Operating Panel to the Ethernet switch.
Ethernet cables
Tip: An Ethernet switch
connected to ETH1 on the rear side of the Processor Unit can also
be used to interface other peripheral systems such as echo sounders
and positioning systems. You can also connect the Olex system to the MF90 system using this Ethernet switch.
- Change the IP Address
on the primary Operating Panel.
Note: Each Operating Panel
must have a different IP Address. None of the panels
must use the default IP Address. If you have previously changed the IP Address on the
Operating Panel, you can proceed to the next step.
- On the Operating Panel,
press Power, and keep it depressed for a few seconds.
The blue indicator
light in the button flashes while the Operating Panel establishes
contact with the Processor Unit. When the connection
has been made, the blue indicator light is lit permanently.
- On the Processor Unit
desktop, open folder SIMRAD-Shortcut.
- Double-click the URL
shortcut to open the Operating Panel configuration page in the default
web browser.
- Select SOP Configuration on the top menu to open the page.
- In the SOP IP field,
change the IP Address from the default value to:
157.237.60.xxThe last digit "xx"
in the IP Address can be any number between 21 and 29.
Note: Each Operating Panel
must have a different IP Address. None of the panels
must use the default IP Address.
- Select Apply IP Configuration.
When the new IP Address has been set in the Operating
Panel, you will loose contact with the configuration page.
- To re-establish contact, use the following URL in your browser:
157.237.60.xx:5000 - Select Sonar PCs Configuration on the top menu to open the page.
- Make sure that the
IP and MAC Addresses to the Processor Unit are correct, and that the
Processor Unit is present on the list.
- Close the web browser.
- Connect and set up the secondary Operating Panel.
- Connect
the Operating Panel to the Ethernet switch.
- On the Operating Panel,
press Power, and keep it depressed for a few seconds.
The blue indicator
light in the button flashes while the Operating Panel establishes
contact with the Processor Unit. When you start the
panel for the first time the interface must be configured to establish
this connection. When the connection
has been made, the blue indicator light is lit permanently.
- On the Processor Unit
desktop, open folder SIMRAD-Shortcut.
- Double-click the URL
shortcut to open the Operating Panel configuration page in the default
web browser.
- Select SOP Configuration on the top menu to open the page.
- In the SOP IP field,
change the IP Address from the default value to:
157.237.60.xxThe last digit "xx"
in the IP Address can be any number between 21 and 29.
Note: Each Operating Panel
must have a different IP Address. None of the panels
must use the default IP Address.
- Select Apply IP Configuration.
When the new IP Address has been set in the Operating
Panel, you will loose contact with the configuration page.
- To re-establish contact, use the following URL in your browser:
157.237.60.xx:5000 - Select Sonar PCs Configuration on the top menu to open the page.
- Obtain the IP address.
- Type or copy the IP address into the relevant box.
- Obtain the MAC address.
- Type or copy the MAC address into the relevant box.
- Select ADD Sonar PC.
- Observe that your Processor
Unit is added to the list.
- Close the web browser.
- Make sure that each Operating Panel is functional.
- Make sure that the
blue indicator is lit, and check that you can move the cursor on the
screen.
- On the Processor Unit
desktop, double-click the MF90 icon to start the program.
Wait until the MF90 system operates
normally.
- Make sure that you can control the cursor,
and that you can make selections in the menu system.
- Press and/or turn selected
buttons, and make sure that the corresponding function is activated
in the user interface.