Whenever required the firmware in the Operating Panel
can be updated to include new functionality or to correct software
errors.
The Operating Panel
is installed as specified in the Installation manual. The Processor Unit is turned on. The following specific
items are required for this task:
USB flash drive
Personal computer (Optional)
Computer mouse (Optional)
Computer keyboard (Optional)
Ethernet cable (Optional)
Chrome web browser
A firmware update for
the Operating Panel was distributed with sonar software version 3.1.8. If this update has not been implemented
you will need to use the Chrome web browser. If you want to use
the Processor Unit you must first connect it to the Internet, then
download and install Chrome.
If the update with
3.1.8 was implemented you can do the firmware update on the Processor
Unit using the default browser.
Neither tools nor instruments
are required. This procedure is made for the Microsoft® Windows® 10 operating system. It is assumed that you are familiar with this operating
system.
Note: The software release note may contain additional details
related to the firmware update.
- Locate the firmware update file: SOPupdate.zip.
- If
you use a separate computer:
- Copy the file to a folder on your computer, but do not unpack it.
- Disconnect the Operating Panel from the Processor Unit. (Ethernet cable)
- Connect the Operating
Panel to the computer.
- Open the web browser.
A firmware update for
the Operating Panel was distributed with sonar software version 3.1.8. If this update has not been implemented
you will need to use the Chrome web browser.
- In the browser address field, type: http://157.237.60.20:5000
Note: If you have previously changed the IP
Address on the Operating Panel, you must use this address to open
the configuration page.
- If you use the Processor Unit:
- Select Power off to turn off the system.
- In the Power Off dialog box, select Exit to Operating System to close the MF90 program.
- If applicable: Connect the keyboard and the mouse to USB sockets on the Processor Unit.
- From the Windows® Start button, right-click to open File Explorer.
- Insert the USB flash
drive.
- Copy the file to a folder on the Processor Unit, but do not unpack it.
- Remove the USB
flash drive.
- On the Processor Unit
desktop, open folder SIMRAD-Shortcut.
- Double-click the URL
shortcut to open the Operating Panel configuration page in the default
web browser.
Note: If you have previously changed the IP
Address on the Operating Panel, you must use this address to open
the configuration page.
- Do the firmware update.
- In the browser window, select Update.
- Select Perform update.
- Locate the firmware update file and select Open.
- Select OK when prompted to
update.
The firmware update will now take place. The web browser will reload. You may need to refresh
the web browser after some time.
- Make sure that the correct versions have been installed:
Refer to the software
release note.
- If
you use a separate computer:
- Disconnect the Operating Panel
from the computer.
- Connect the Operating Panel to the Processor Unit. (Ethernet cable)
- On the Processor Unit
desktop, double-click the MF90 icon to start the program.
- Restore normal operation.