Hull Unit
Hull Unit is located on the left side of the top bar. Select it to open the Hull Unit Control dialog box.

Description
The Hull Unit Control dialog box allows you to lower and hoist the transducer. The dialog box also provides status information about the transducer position. You can monitor the current position of the transducer and make changes to the position defaults. The current position of the transducer is shown on the top bar. The colour is used to provide status information.
- Red colour: The hull unit is disconnected.
- Green colour: The hull unit is connected and available for use.
- Grey colour: The hull unit is connected and in use.
A warning message is displayed if a malfunction occurs while you are lowering or hoisting the transducer. Select Acknowledge to accept the message. Investigate the cause of the error message before you proceed.
Retracting the transducer to a middle position may be useful if you use the ST90 system simultaneously with other sonars. If you have the large hull unit you can define two middle positions.
Related functionality
- Hull Unit Control dialog box
Select Hull Unit on the top bar to open the Hull Unit Control dialog box.
The Hull Unit Control dialog box allows you to lower and hoist the transducer. The dialog box also provides status information about the transducer position. You can monitor the current position of the transducer and make changes to the position defaults.
- Hull Unit Configuration page (Installation dialog box)
The ST90 system can be provided with different hull units. The main difference between these hull units is the length of the transducer shaft, and thus also the physical height of the entire hull unit assembly. The same transducer is used on all hull unit types. Select which type of hull unit that has been installed. You only need to do this once.
Note:The choice you make is vital for all operation. An accidental change to the setting may cause damage to your ST90 system.
This page is located in the Installation dialog box. To open the page, select Installation on the Setup menu.
- Hull Unit page (Diagnostics dialog box)
Use the Hull Unit page to read the software and firmware versions from the Hull Unit Control board.
This page is located in the Diagnostics dialog box. Open the Diagnostics dialog box from the Setup menu.